High technology in IPL treatment The
recent tools suitable for flash-light treatments offer new,
great and enormously expanding possibility on the areas of
permanent epilation, skin regeneration and treatments
of acne, mole and vascular deformations. The permanent epilation is the
most frequent and quickly spreading procedure. At least 90%
of the Western European and American women use some kind of
epilation regularly - e.g. shaving, resin, depilating
creams, electrolysis and epilation by laser. There
are a lot of disadvantges of the before mentioned procedures;
they are painful,
slow, complicated, they have only interim
effects or expensive. The
new iPulse i200 technology provides a solution
for elimination of the above listed disadvantages.
Recently a lot of
our patients asked why Ars Medica Laser Clinic does not
extend its activity to this area utilizing its 15-year
experience. Up till now we have not tried to expand our
activities on this area because on one hand in our opinion
such cosmetic treatments are incompatible with the activities
of such a clinic which makes surgical actions and on
the other hand we have not found the right tool suitable
for the correct solution of the above mentioned problems.
But our opinion has changed because we could find the
right tool and technology which can guarantee the best
result and thus Ars Medica Laser Clinic can undertake
these treatments, too. During studying the tool and the
activity it appeared that it could be a great advantage
for the patient if these treatments will be made in a
clinic by the help of a medical background. Because the
detailed examination before the treatment - which covers
not only the treated area but other diseases of the patient,
too (e.g. diabetes, hormonal diseases, etc.) - and the
early recognition and special treatment of allergic responses
and complications arising during the treatment or after
it demands the medical background. If it is available
it is an advantage not only for the patient but for the
one making the treatment, too.
The newly established activities
meet the regulations of the quality policy and the operation
of the clinic therefore its documentation is a bit more
detailed than that o fan average cosmetic treatment (e.g.
photo documentation), but our principle is that there are
no small or big surgical actions, the conditions and documentation
of all the medical action should be prepared accurately
because it provides satisfaction to everybody. This is
the common denomination of the method when short flashing
lights originating from Xenon flashing lamp are used for
the treatments. The energy of light is absorbed by melanine
located in the hair, it is converted to thermal energy
and if the temperature reaches 70 degree of Centigrade
in the follicule it kills the hair generating cells and
hair generation in that fullicule ceases definitively.
In case of haemangiomas the light is absorbed in haemoglobin
of the blood and puts out its effect while in case of moles
it is absorbed in the melanine.
The earlier high performance
IPL machines used alternate current for supplying the Xenon
lamp thus the spectrum
of the emissioned light changed because of the change of
the current intensity. Beside the visible light the spectrum
contains ultraviolet (UV) and infrared (IR) wavelengths,
too. Since these wavelengths are "harmful" from
the point of view of the treatment, they should be eliminated
from the system. In the earlier machines colour filters
were used to prevent the emission of harmful radiation
from the treating head. In turn it causes significant energy
loss therefore the energy emitted by the machines should
be enhanced which eventuates the improvement of heat loading
of the skin. Therefore the heat sense also rises. The iPulse
technology uses square-pulse current therefore the spectrum
of the emitted light will be constant because of the constant
current intensity. Thus the machine can be operated at
a lower energy level with significantly smaller surrounding
heat load. Moreover the use of expensive and complicated
colour filters will not be required because only the light
with optimal wavelenght will be emitted by the machine.
Some IPL systems can produce several impulses during one "shot" which
permits the decrease of the temperature of the skin between
the impulses while the temperature increses in the target
structure (e.g. fullicule). THis is a more complicated
technology which results in higher temperature in the target
structure without redundant warm of the surrounding skin.
 The iPulse i200 technology is the most advanced and most
regulated flash-type technology nowadays. By the help of
the computer it can produce single or triple combined impulses.
In the multiple impulse mode the length of the individual
impulses and the interval between the impulses can be adjusted.
The several adjustment variations make it possible to find
the ideal adjustment combination for every patient which
provides the adequate warm up of the target structure beside
the smallest possible heat sense.
Almost all the earlier flash-type sstems uses one linear
Xenon lamp which resuts in a rectangular treatment area.
It is typical of these systems that the emission of energy
is larger at the central part of the lamp that at the edge
therefore larger overlapping should be used during the
treatments. The iPulse technology uses low energy twin
Xenon lamps, which provide even energy distribution all
over the large - 8.9 cm2 - treatment area, there is no
loss at the edges therefore overlapping is not necessary
which also results in smaller heat sense.
Back to the Cosmetology
Abdominoplasty |
Acne
treatment |
Breast
augmentation |
Breast
reduction |
Dentistry |
Ear,
nose, throat |
Gynecology |
Hemorrhoid
surgery |
Lipoma |
Mole
treatment |
Orthopedics |
Permanent
epilation |
Plastic
surgery |
Removal
of pigmented naevi |
Removal
of teleangiectasia |
Removal
of warts |
Rhinoplasty |
Surgery |
Surgery
for hernia |
Surgery
for phimosis |
Urology |
Varix
surgery
Sitemap
- magyar |
Sitemap
- deutsch |
Sitemap
- english
|